Skip to main content
Join
zipcar-spring-promotion

Osha scaffold tagging requirements

The yellow tags outline special safety precautions or usage guidelines that all users must follow. Work Permit Issuer & Receiver Role. 32 (f) ]. Once you have your competent person established, they need to keep track of their scaffolding inspections. The employer must ensure damaged or defective equipment is removed from service immediately and replaced; 1915. 21 (b) (2) as these relate to the hazards of work on scaffolds. Green Tags will be hung on scaffolds that have been inspected and Scaffolding. Every platform must be planked and decked as fully as possible with the space between the platform and uprights not more than 1 inch (2. Fall Protection above 10’ ( or as required by the legislation from your jurisdiction if less) OSHA standard 1926. Scaffold platforms must be fully decked or planked. According to the agency, a competent person is one who: Has been trained to understand the requirements of OSHA’s scaffold standards (29 CFR 1910. . The final rule sets scaffold capacity requirements that are substantively the same as those in existing subpart L, while eliminating ambiguities and apparent (2) If the lanyard is attached to a supported scaffold structural member, the scaffold must be properly braced and tied-in to the structure before being used as an anchorage point and must meet the requirements of 1926. With this checklist, you can do the following: Capture general information about the structure. Scaffold Inspection & Tagging Criteria. 30; 1910. These tags serve as visual indicators, providing important information and warnings to workers and visitors. 452. What is a narrow frame. The inspection will be recorded on the daily safety inspection required by Section 01. Oct 18, 2017 · 1. gov. 0. NOTE : Except where indicated, these requirements also apply to multi-level, single-point adjustable, multi-point adjustable, interior hung, needle beam, catenary, and float (ship) scaffolds. Does the competent person have to be qualified in safety issues relating to the use of the scaffold, such as guardrails and fall arrest equipment, or just in safety issues relating to scaffold erection and structural integrity? The standard does not specify particular training requirements for competent persons. Build a staircase if the scaffold will be used for a length of time. quipment. Know the weight capacity of the scaffold. Figure 3: Bird cage tower scaffold. Aerial Lifts. Our interpretation letters explain these requirements and how they apply to particular circumstances, but they cannot create additional employer obligations. This section highlights OSHA standards and documents related to scaffolding. Use your safety belts and lanyards when working on scaffolding at a height of 10 feet or more above ground level. 28(g)(8)). 451 (g) (1), anyone working on a scaffold more than 10 feet above a lower 1910. 03 When scaffolding is in use, they will be inspected daily by the CP, prior to each shift. 23 (a) (2) Designed into or is an integral part of machines or equipment. (3) All stationary scaffold legs, including those of outriggers Q. ”. These Regulations may be cited as the Workplace Safety and Health (Scaffolds) Regulations 2011 and shall come into operation on 10th September 2011. When the employer can demonstrate that it is not feasible or creates a greater hazard to use guardrail, safety net, or personal fall protection systems on residential roofs, the employer must develop and implement a fall protection plan that meets the requirements of 29 CFR 1926. Jul 25, 2022 · Scaffold tagging is an essential component of a comprehensive scaffold safety program, reinforcing the commitment to safety and compliance with regulatory requirements. Use the provided access. 451 for the construction industry) Is capable of identifying scaffold hazards In addition, OSHA requires that fall protection be provided when working over dangerous equipment and machinery, regardless of the fall distance. On scaffolds whose length is greater than their height, longitudinal bracing must be repeated beginning at least at every fifth post. Due to their versatility many contractors use them instead of ladders because they allow workers to maintain their balance and work more easily from the. scaffold components to gain height while working on a scaffold platform; and, • Where swinging loads are being hoisted onto or near scaffolds such that the loads might contact the scaffold, tag lines or equivalent measures to control the loads shall be used. Design requirements: Scaffolding must be designed by a registered professional engineer and must be able to support at least four times the intended load. 452(w)(6)]: 1926. Remove snow and ice from scaffold platforms, ladders and access areas. 1926 Subpart L App A (1) (b) (ii) The maximum permissible span for 1¼ × 9-inch or wider wood plank of full thickness with a maximum intended load of 50 lb/ft. 1910. Set] 978-1-74361-775-5 [PDF] 978-1-74361-776-2 [DOCX] GUIDE TO SCAFFOLD INSPECTION AND MAINTENANCE. 452(w)(4)] Employees are not allowed to ride on scaffolds unless the following conditions exist [29 CFR 1926. Check requirements in the legislation applicable to your Jun 12, 2023 · FAQs About Safety Tags. Scaffolding. principal contractors for a ‘construction project’ where the cost of construction work is $250 000 or more. Other types of equipment, principally scissor lifts and aerial lifts, can be regarded as other types of supported scaffolds. au | Web www. Is the supporting surface where the scaffold is going to be erected capable of withstanding the weight of the scaffold? OHSR 4. Holman: You have submitted nine letters to the Occupational Safety and Health Administration (OSHA) containing a number of questions on the construction scaffold standard (29 CFR Part 1926 Subpart L). PURPOSE This General Instruction (GI) provides the minimum administrative requirements for the safe design, erection, supervision, inspection, use, alteration, and dismantling of stationary and mobile scaffolds with fixed platform heights at all onshore and offshore Saudi Aramco facilities and project sites. The Occupational Safety and Health Administration (OSHA) hereby revises the construction industry safety standards which regulate the design, construction, and use of scaffolds. A partially erected scaffold may not have guardrails, or ladders, and be properly tied or be fully planked. Oct 16, 2019 · Check out our clear pouches at the bottom of the page! • High-strength grommets and reinforced eyelets offer superior durability and pull-strength for a Scaffold Safety Tag that last longer in tough conditions. SCAFFOLDS. 27 (b) (2) (iii) Each employee who uses the rope descent system is trained in accordance with § 1910. (a) Scaffolds shall be provided for all work that cannot be done safely by employees standing on permanent or solid construction at least 20 inches wide, except where such work can be safely done from ladders. By way of training and/or Specific regulatory requirements. However, these changes have the potential to introduce new hazards or risks. For example, there are periodic inspection requirements for welded frame scaffolds (§1910. 503(a) and (c). 1926 Subpart L App A (1) (c) Fabricated planks and platforms may be used in lieu of solid sawn wood planks. Scaffolding inspection tags can be ordered from a variety of A unique scaffold identification tag number must be clearly identified on all tags for tracking purposes. 451(a) Capacity Paragraph (a) sets the minimum strength criteria for all scaffold components and connections. A risk assessment may find the need for more frequent Energy control program. However, by using scaffolding tags, most of these scaffolding accidents can be controlled. 8-2019 standard). All scaffolds shall be inspected after erection as per OSHA requirements. Follow manufacturer’s guidelines for proper erection, use and dismantling. Supported scaffolds and work platforms must be inspected by a professional engineer or a competent person designated by the supervisor. Must I use a tag system on a scaffold? A. SUBPART L. 1 We are responding in a series of The Fall Protection Height Regulation for Scaffold. 453 (b) (2) (v) requires workers to wear a body belt, with a lanyard attached to the boom or basket, when working from an aerial lift. They shall not be used in place of, or as a substitute for, accident prevention signs. 502(k) and training that meets the requirements of 29 CFR 1926. Dear Mr. Your questions related specifically to Baker style scaffolds and whether a person could move and work from this type of scaffold, without dismounting, with the casters in Jan 31, 2024 · Meaning: “ CAUTION ” tag(s), wish replace all unsophisticated “Safe Scaffold” tag(s) whenever the scaffold is been modified to meet work requirements, and as a result, could present a hazard to the user. 453. 451(a)(6) Nov 4, 2020 · Scaffold safety requirements for platform construction. Types include: Extendable boom platforms, Aerial ladders, Articulating (jointed) boom platforms, Vertical towers, and. Scissor lifts are mobile supported scaffold work platforms used to safely move workers vertically and to different locations in a variety of industries including construction, retail, entertainment and manufacturing. If so, the employer must meet the requirements in Option (1), Option (2), or Option (3) of this section, as follows: a. Scissor lifts are different from aerial lifts because the lifting mechanism moves the work platform Jan 28, 2024 · Yellow scaffold tags—Yellow tags indicate that scaffolds have undergone modifications to their structure or components to fulfill particular work requirements. 451 (h) (2) OSHA requirements are set by statute, standards and regulations. Tag and restrict use: Tag and restrict access to any unsafe scaffolds until repairs are made. Additionally, almost 25% of workers receive no safety training for erecting scaffolds and installing work platforms. 5 centimeters) wide. (a) – The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the PRELIMINARY. Scaffold inspection before use: Before placed in service a scaffold must be inspected to conform that the erection has been done in accordance with the design drawings. 157 (c) (4) Jun 8, 1998 · This is in response to your letters, dated June 12, 1997, addressed to Mr. 1915. These are but a few tips that can help us avoid accidents while working on scaffolds. ScaffoldsNarrow frame scaffolds, also known as Baker/Perry style scaffolds, are among the most popular pieces of construction. platform. Scaffolding » Scissor Lifts. For technical assistance, please refer to OSHA’s eTool and other resources on scaffolding. OSHA Fact Sheet (Publication 3760), (November 2014). Recordkeeping Requirements and Forms ; Safety and Health Programs ; Scaffolds; Part Number: 1926; 1-800-321-OSHA 1-800-321-6742 Learn about the importance of scaffolding safety, OSHA scaffolding safety requirements, scaffold safety guidelines, and scaffold tag business. 1. [29 CFR 1926. 71 (d) (1) Metal scaffold members shall be maintained in good repair and free of corrosion. After tagging, prepare a Safety Tips for Working Safely with Scaffolds. Scaffolding safety tags are an important resource for the use of any type of scaffold. Scaffolds can be the source of multiple types of hazards in the workplace, including falls and falling objects. Pre-shift Inspection Required Before Use as Indicated Below” and 6. Scaffolds (Staging). 2. 451 for the daily inspection of scaffolds. This can be done with a scaffold tag. This Each scaffold and scaffold component must support without failure its own weight and at least four times the maximum intended load applied or transmitted to it. 451. 3 October 30, 1978 -2-(1) Rope or chain shall be secured to each support and taut at all times. 3 million construction workers, or 65 percent of the construction industry, work on scaffolds. • Use red, green and yellow tags to help identify scaffold or equipment conditions. Take corrective action: Immediately address any deficiencies that pose an immediate safety hazard. Level the scaffold after each move. Ensure that scaffold is securely attached to the building structure. We apologize for the delay in responding. 451(a)(6), scaffolds must be designed by a qualified person (defined in §1926. 2 shall be 4 feet. While not explicitly required by OSHA, we believe all scaffolding should have a scaffold tag on the bottom of it. While the provisions of May 6, 2024 · This free scaffold safety inspection checklist template can be used by scaffolding inspection professionals to conduct assessments of scaffolding work to ensure safety. There are many important safety considerations in working with scaffolds including the selection of the appropriate scaffold, proper assembly, training, inspections, and use Oct 1, 2017 · Scaffolding is naturally unstable because it is usually a tall structure with a narrow base. This section supplements and clarifies the requirements of 1926. Select the right type for the job. 8 standard in 1969, scaffolding work has evolved considerably as 1926. Inspect daily and before each use. Scaffolding inspection should be May 12, 2023 · These requirements include: 1. 2, a Scaffold shall not require permits if: Supported Scaffold: A supported scaffold that is less than 40 feet in height; not an outrigger scaffold; without any hoisting equipment over2000 pound capacity; and is not designed to be loaded over 75 pounds per square foot, does not need a permit May 20, 1994 · OSHA requirements are set by statute, standards and regulations. This flag show spezial requirements for safe use. FactSheet. ( a) Capacity. 4 metre horizontal interval, (c) anchored by one tie‑in for each 3 metre vertical interval and one tie‑in for Feb 6, 2023 · Fall Protection. Mar 26, 2010 · Standard Interpretations. 452 – Additional Requirements to Specific Types of Scaffolds • 1926. 22. For construction activities, go to Part C-1, in Safety Standards for Construction Work, Chapter 296-155 WAC. B. 13 and on the scaffold tag. OSHA Fact Sheet (Publication 3759), (November 2014). Many scissor lifts are covered under OSHA’s Scaffolding standard. " It was not our intention to suggest that scaffold stairs that do not meet the Subpart X requirements, but do meet Subpart L requirements, are citable. Use of toeboards across scaffold access points. For example, Subpart M (horizontal) tells us that, in construction, you must have fall protection beginning at 6 feet [29 CFR 1926. The wood must be clear, free of loose knots, splits, or other defects. OSHA Instruction STD 3-10. An aerial lift is any vehicle-mounted device used to elevate personnel. Scaffold users checklist is divided into 9 elements and each element will be discussed in detail; Foundation igned per the scaffold manufacturer instructions. The use of chain and synthetic, fiber, or wire ropes as top rails and intermediate rails of guardrails used on scaffolding meets the equivalent requirements of 1926. Describes common hazards and possible solutions for tasks performed during the ship repair process. Scaffolds should be capable of supporting up to four times their maximum load. [ 29 CFR 1926. 157 (c) (2) Only approved portable fire extinguishers shall be used to meet the requirements of this section. 200 (h) (2) Determine if any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could get closer than 20 feet to a power line. 450. scaffolding contractors and workers who carry out scaffolding work, and. Red , Green, Yellow Tag Scaffolds . 978-1-74361-780-9 [Multi-Vol. Nov 17, 2003 · You ask about requirements in the construction scaffold standard, 29 CFR 1926. Provides general requirements for all scaffolds and also includes information on specific types of scaffolding. 17 2. 451 (g) (1), each employee on a scaffold more than 10-feet above a lower level must be protected from falling to that lower level (also note American National Safety Institute/American Society of Safety Professionals (ANSI/ASSP) – Scaffolding Safety Requirements A10. Is there any potential for contact with exposed electrical equipment and conductors (i. Design and construct to standards. Therefore, it would be a hazard and fall under the defective equipment category until the May 16, 2024 · Always check inspection tags. Although tag systems are not a legal requirement, the law does require inspection of scaffolding from which a person might fall 2 metres or more and the issue of a report by a competent person, on completion and at least weekly thereafter. Jun 24, 1992 · My explanation is that 29 CFR 1926. Additional Information. Forklifts, trucks, motor vehicles, or add-on motors must not be used to propel scaffolds unless the scaffold is designed for them. Per BC 3314. Roy Gurnham and myself, asking for a clarification of OSHA's mobile scaffold standard §1926. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the This section does not apply to aerial lifts, the criteria for which are set out exclusively in § 1926. 454 – Training Requirements. au. This threshold differs from 29 OSHA standard 1926. ( 1) Except as provided in paragraphs (a) (2), (a) (3), (a) (4), (a) (5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the Feb 1, 1999 · There are periodic inspection requirements for a number of different types of scaffolds. 28(d)(14)), mason's adjustable multiple-point suspension scaffolds (§1910. The handover certificate should be kept at the workplace until the scaffold has been dismantled. Feb 23, 2000 · Consequently, scaffold stairs which meet all of the requirements of Subpart X may be used for temporary access to upper floors while constructing multistory buildings. (1) Metal scaffolds shall be designed to support all dead, live, and wind loads to which they will be subjected. Sample of types of installation or erection of scaffold -. Tube and Coupler Scaffolds - Planning and Design. Mar 22, 2024 · Guardrails should be within the height range of 38” to 45”. The locking device shall be of a type which has no loose parts. Conversely, the Competent Person must also oversee the disassembly of scaffolding, as well as the movement of any scaffo. 6 m) on either side of the splice, overlap the abutted ends equally, and have at least the same cross-sectional areas as the pole. 452(b)(3) ] On scaffolds whose length is less than their height, longitudinal bracing must be installed from the base of the end posts upward to the opposite end posts, and then in alternating Feb 12, 2019 · Green – Green scaffolding tags indicate that a section of scaffolding has been inspected and certified as completely safe to use – with proper bracing, platform support, guardrails, anti-slip devices, and all other precautionary measures that are required by Work Safe Australia. As a construction worker or site manager, you understand the critical role that scaffolds play in ensuring the safety and efficiency of construction projects. November 14, 2022. We have paraphrased your questions as follows: Question (1): What OSHA construction scaffold requirements apply to attachable (bolt-on) scaffold ladders? Is fall protection required for According to Federal labor statistics, more scaffold incidents are attributed to planking giving way than any other cause. 8-2019, Scaffolding Safety Requirements, establishes safety requirements for the construction, operation and use of scaffolds used in the construction, alteration, demolition and maintenance of buildings and structures. They are typically attached to equipment, machinery, structures, or hazardous areas to remind or alert individuals, highlighting All scaffolds shall be inspected after erection as per OSHA requirements. Why is Scaffold Tagging Important? Scaffold tagging is important because it helps create a visual guide that workers can follow when erecting and using the scaffold. Scaffold-related accidents account for 4,500 injuries and over 60 deaths every year, resulting in $90 million in workdays lost. Green Tags will be hung on scaffolds that have been inspected and are safe for use. Tag Number Three, green in color, with legend that reads “Attention. 1 centimetersm) when side brackets or odd-shaped structures result in a wider opening between Metal Scaffolds. Many general contractors require this on their projects. 23 (a) (1) Used in emergency operations such as firefighting, rescue, and tactical law enforcement operations, or training for these operations; or. WAC 296-874-40022 Meet these requirements when using form scaffolds and carpenter's bracket scaffolds. Design and Permit Requirements. 3. 452(w). 28(f)(11)), and two-point suspension scaffolds (§1910. 23 (b) General requirements for all ladders. 451 or 1926. To counteract this, the scaffold must be braced or tied off to a stable structure such as a ship’s hull or building wall. e • 1926. swa. Yellow “CAUTION” tags are used whenever the scaffold has been modified to meet work A unique scaffold identification tag number must be clearly identified on all tags for tracking purposes. Exceptions: 1. Scaffold Tags. 157 (c) (3) The employer shall not provide or make available in the workplace portable fire extinguishers using carbon tetrachloride or chlorobromomethane extinguishing agents. To prevent employees from being injured from falls, employers must: Guard every floor hole into which a worker can accidentally walk (using a railing and toe-board or a floor hole cover). Per 1926. Work of a limited nature and of short duration when the permanent or solid construction is less Dec 14, 2023 · The Importance of Scaffold Inspection Tag Requirements. Narrow Frame Scaffolds. Employers and construction project management must ensure that workers are safe on Where wooden poles are spliced, the ends shall be squared and the upper section shall rest squarely on the lower section. The employer must ensure: Swinging scaffold; (viii) ld;(ix)(x)(xi)Window jack scaffold; Mobile scaffold or scaffold on wheels or skids; and Cantilever, jib, figure or. How & Why to tag a scaffold. In these Regulations, unless the context otherwise requires —. The American National Standards Institute (ANSI) Scaffold Tagging System. This Scaffold Was Built to Meet Safety Regulations” and with space for a dated authorized signature. 2 and 13. A. 04 Scaffolding that has been hoisted after configuration or assembly shall be re- Nov 14, 2022 · Scaffolding Safety and Scaffolding Tagging. (OSHA FS 3722 - 2014) (English: PDF ) Scaffolding: Ladder Jack Scaffolds Fact Sheet. All scaffold identification tags will be of solid green, yellow, or red color with black lettering. Any combination of the above. (a) supported against lateral movement by adequate bracing, (b) anchored by one tie‑in for each 4. 502(d), which defines the criteria for anchorage points and other components of a personal fall arrest system. This letter constitutes OSHA's interpretation of the requirements discussed. Safety tags play a vital role in maintaining a safe and compliant work environment. Jun 17, 2005 · Re: Requirements for being designated a competent person under Part 1926 Subpart L (Scaffolds). Scaffolding safety tags are typically used after an Aug 27, 2022 · The 10 OSHA Scaffolding Requirements. 200 (h) (1) requires warning tags to be placed on any existing hazard such as a defective tool or equipment. Figure 2: Putlog scaffold. Mar 9, 2021 · Identify requirements for the inspection of the scaffold. 28 for general industry and 29 CFR 1926. The planking portion of OSHA's Scaffolding eTool is intended to address the need for specific and accurate To review ladder access requirements, please refer to the OSHA Standard 29 CFR 1926. 451(e), regarding attachable ladders. Ensure the foundation and base of the scaffolding is secure and check that the Apr 25, 2008 · OSHA requires a “competent person” to inspect scaffolds. requirements are more properly located in §§1926. -. Inspection of scaffolding is a key safety element of the scaffolding process. activities are done safely;The Competent Personmust also inspect scaffolding as soon as it has been erected, as well as before first use on each shift, to identify any haza. Since the original approval of the A10. Safe Work Australia Contact Information Phone 1300 551 832 | Email info@swa. 451(a)(1) A qualified person must design the scaffolds, which are loaded in accordance with that design. Paragraph 1926. 71 (d) (2) All vertical and horizontal members shall be fastened together with a coupler or locking device which will form a positive connection. Do not extend adjusting leg screws more than 12 inches. Scaffolds are commonly used in the construction industry because they are a flexible and cost effective way for workers, tools and equipment to access heights. A red tag signifies that the scaffold is unsafe and should not be used under any circumstances. By tagging equipment, workers can know if scaffolding has been inspected or is safe to use. Load requirements: Scaffolding must be able to support the weight of workers, equipment, and materials without collapsing. There are two basic types of scaffolds: Suspended scaffolds, which are one or more platforms suspended by ropes or other non-rigid, overhead support. (2) No metal scaffold equipment that is broken or deteriorated to the extent that its section is structurally weakened shall be used. Nov 29, 1996 · §1926. Standard Number: 1926. These regulations are designed to address a range of potential hazards, from falls to structural instability, that workers may face while on or around scaffolding. 450 as one who, by possession of a recognized degree, certificate, or professional standing, or who by extensive knowledge, training and experience, has successfully demonstrated his/her ability to solve or Apr 18, 2019 · ANSI/ASSP A10. OSHA eTool. Jul 19, 2023 · A green tag indicates the scaffold is safe to use, while a yellow tag means some issues must be addressed before the scaffold can be used safely. 200 (h) Accident prevention tags. Scaffold incidents causing injury or death to workers are often caused by the planking or support giving way, by a worker slipping, the absence of fall protection, or being struck by a falling object. Maintain stability at all times. (OSHA FS 3857 - 2016) (English: PDF ) Scaffolding: Tube and Coupler Scaffolds - Erection and Use Fact Sheet. 27 (b) (2) (iv) The rope descent system is inspected at the start of each workshift that it is to be used. “work platform” means a platform which is used to support persons or materials, and includes a working stage. OSHA Fact Sheet (Publication 3722), (April 2014). Wood splice plates shall be provided on at least two adjacent sides, and shall extend at least 2 feet (0. 451(a)(5) when in compliance with the following guidelines. The space must not exceed 9 inches (24. SUMMARY. 1926. (OSHA FS 3759 - 2014) (English: PDF ) 1910. Scaffolding Safety Checklist page 1 of 3 General requirements Yes No If No, next steps Regulatory reference 1. Replaces traditional shipyard scaffolding. Aerial lifts have replaced ladders and scaffolding on many job sites due to their mobility and flexibility. A scaffold is an elevated, temporary work platform. Don’t climb using railings. (a) General. How Green Scaffolds tags are filled. Part IV-Scaffold users checklist. 200 (h) (1) Accident prevention tags shall be used as a temporary means of warning employees of an existing hazard, such as defective tools, equipment, etc. A secure scaffolding height-to-base ratio of over 4:1 requires proper securing with guying, tying, bracing, etc. Tube and Coupler Scaffolds - Erection and Use. Power systems used to propel mobile scaffolds must be designed for that purpose. Green Tags will be hung on scaffolds that have been inspected and An OSHA "competent person" is defined as "one who is capable of identifying existing and predictable hazards in the surroundings or working conditions which are unsanitary, hazardous, or dangerous to employees, and who has authorization to take prompt corrective measures to eliminate them" [ 29 CFR 1926. OSHA requires the general contractor in section 1926. According to OSHA, an estimated 2. Build a rest platform for every 10 m (30 ft) in height beside the ladder. The planking used must be “scaffold grade. Dec 6, 2023 · Record any identified deficiencies: Clearly document any problems identified during the inspection. 451(e) or the Supported Scaffolds module. The main duties are set out in Table 1. (OSHA 3150 - 2002) (English: PDF ) Scaffolding: Narrow Frame Scaffolds Fact Sheet. For personal fall arrest system requirements in this chapter, go to WAC 296-874-20058. Scaffolding is addressed in specific OSHA standards for general industry, maritime, and construction. Each company or organization should ensure scaffolds are properly designed erected and inspected by a certified inspector using an appropriate inspection check list or tagging system. To ensure the safety of workers when using scaffolding in construction, OSHA issued several scaffolding standards found in 29 CFR 1926 Subpart L. Figure 1: Independent scaffold. 6 metre vertical interval and one tie‑in for each 6. 324 (1) An employer must ensure that a single pole or double pole scaffold is. Simply put: Any rules in a vertical standard, like Scaffolds, override any rules in a horizontal standard, like Fall Protection. Have a handhold above the scaffold platform. May 21, 1999 · 1. 501 (b) (1)]. Aug 4, 2000 · Under the general scaffold requirements, in 29 CFR 1926. Aug 5, 1997 · This is in response to your letter of June 12, 1997, to the Occupational Safety and Health Administration (OSHA) requesting an interpretation of the requirements in paragraph 1926. This tagging system makes it easy to understand the scaffold’s safety status. And Tag Number Four, color not specified, with legend on the one side that reads “Scaffold Use Tag. 451(f)(3) to have scaffolds and scaffold components inspected for General Requirements. ew hd qd ow mn ry bt ac yd px