When hubby turns it on it blow cold air and then cuts off. Dec 4, 2019 · Member. Posts: 116. If any of the following signs appear in your thermostat, then it’ll start malfunctioning or get turned off, even if the furnace is running constantly! So, replacement would be the solution to succeed in dealing with a bad thermostat. Your furnace heats the air in your home and distributes it through ductwork in routine cycles. If the sail switch doesn't report air flow, the control board turns the blower off. You should hear a click and might be able to smell propane in the Jun 10, 2021 · Then before you turn the system on, sniff around the furnace to see if you can smell any gas. Low airflow. Feb 16, 2016 · I am trying to figure out how to find the flame sensor on my Atwood furnace for my RV. nothing happen? 3. Thermostat says furnace is on, getting 13. Inspection and repair of ductwork. Sep 28, 2022 · Make sure that it’s set to “Heat” or “Furnace. When it cools, it will restart, and the 2. The on/off switch at the top is very hard to click on and off and also the temp slide on the bottom is difficult to determine at what setting it is being set at, you have to sort of slide it back and forth to get it to a comfortable temp. If the motor runs but nothing else happens, look to the possibility of a failed sail switch or high Mar 3, 2024 · Atwood Furnace will not stay running. Join Date: Sep 2017. My hope is that the sensor is dirty. The blower runs for a couple more minutes and finally shuts down. The blower does not Mar 16, 2023 · Atwood 7920-II Troubleshooting. Thermostat calls for heat 2. fan comes, flame ignites, but goes back out, relights and repeats? if 1. THAT is the blue wire that would go to furnace. A few seconds later, the burner ignites (you can hear it and feel the warmth from the exhaust outside). This is part 1 in a sears of videos for the operation, diagnosis and repair of an Atwood furnace. Oct 15, 2017 · Junior Member. From the start the furnace would start the blower and after a few Feb 11, 2023 · Occasionally we get lucky and it turns on and runs for a while. A continuous run until the thermostat is satisfied is ideal but not possible in all scenarios. Clean the filter with dish-washing liquid and soap, and rinse thoroughly. It will heat up the house and turns off automatically when it reaches my desired temperature setting. I have a Atwood 7920 that does not turn off. I can repeat the cycle by turning the thermostat off and waiting a couple of minutes, then turning it back on. Should not cost you anything but time. The furnace is circuitry is attempting to 'prove' there is ignition and a flame and cannot so it shuts down after 3 attempts. My atwood furnace, model 8525-IV, blower will not shut off, if powered - shore power or 12v batt. Atwood Furnace will not Start. It takes about 20 minutes before I can restart it. Burner chamber overheats (there is a high temperature limit emergency shut-off) #1 is low batteries and probably only applies if not plugged to shore power. This stop-start routine is far from normal or healthy behavior. The fan will blow for 2-3 seconds then stop, then approx. NO 12VDC at Furnace then bad wire between thermostat/furnace. There will be the same 20-second delay that happens on your furnace when you power up the water heater. Dec 21, 2022 · Atwood furnace model AFLA40. Eventually, the burner will start again. At the same time, your blower turns on to help cool it down. Pulled the panel cover down and there are (4) wires on the top of the furnace with (3) connected. When the temperature in your home reaches your desired level, your furnace stops for a period. 2015 Backpack SS1500. Check Wiring. Have not had to reset furnace switch doing it this way. Replaced thermostat. If you haven’t replaced it in 30 days to 6 months, it’s time to clean or replace it. Mar 1, 2022 · If your furnace won’t turn on automatically or is frequently turning off and on, check the air filter for dirt and grime. The air intake and exhaust vents are clear. The blower comes on and the propane ignites runs for a min, shuts off, blower stays on, propane ignites again stays on a min, then shuts off, blower is still going, propane ignites again etc etc. Go to 6. Atwood 8531 furnace problems. There is a red light that blinks twice repeatedly … read more Feb 10, 2014 · Join Date: Sep 2011. Mechanic's Assistant: Sometimes things that you think will be really complicated end up being easy to fix with a RV. I have a 2006 Bounder with a Atwood 8535-IV-DCLP furnace. There are 4 wires leaving the furnace. Have two Atwood's on same propane … read more. This is to be done by hand only and never use tools. Mechanic's Assistant: Just to clarify, what are the exact lights you're talking about? Lights the burner puts out Apr 10, 2017 · Location: Parma, NY. When turning the thermostat to gas I hear the converter box come on for a few seconds but nothing else. I have a 2002 Bounder 39R with two Atwood 8520 IV DCLP furnaces. The blower kicks on and runs its cycle, the burner kicks in after 15 seconds or so, then shuts off after 5 or 6 seconds. The furnace keeps turning off as it lights. Gas valve turns on. If these blades become dirty, it won’t work as efficiently or sometimes at all. Mar 12, 2022 · The first step is to check the furnace for a switch, most newer Atwood's have a reset switch on them. On Rv starts, runs, ignites for 20 seconds then shuts off. Oct 27, 2017 · O. Allot Jan 24, 2018 · Atwood 8520 Furnace problem. Join Date: Apr 2015. Feb 5, 2021 · Posts: 1. Your unit may run for a few minutes before shutting off abruptly and restarting a cycle. Sep 19, 2023 · The way to narrow this down is to go ahead and start it up and run it until it quits heating and then disconnect the thermostat lead and see if that turns it off or not. Jan 11, 2024 · Join Date: Aug 2023. It behaves like an indecisive weather vane, changing its operation mode frequently. The thermostat is not set to Heat or a high enough temperature. This is roughly anywhere from 2 seconds to 2 minutes on and then off again. Upon resetting the rocker switch, the furnace can be turned on again runs for five minutes then shuts down again with rocker Nov 20, 2023 · It’s actually normal for your furnace to turn on and off throughout the day. When turned on, the fan comes on and the burner ignites normally, but the burner shuts off after a few seconds. The furnace fan will start running but no heat. The 8500 or 8900 models are the most compatible with your Atwood heater and should plug in easily. The furnace runs on 12-volt power, whether the RV is plugged into 120-volt electric or not. Location: Moncks Corner, sc. Posts: 35. 2 *Power Switch (Door Models) *Switch is located behind door • Turn the thermostat to the lowest setting . Fan speed drops too low. Between a couple of seconds to a minute later, the burner/flame turns off (the fan Jan 12, 2020 · Hello and Help! My new atwood furnace will not ignite. Location: Fayetteville NC. I checked the circuit board and the red light flash once stops then flash again. Hello, I have a 2006 Damon Challenger motorhome. The blower wheel has blades that push the air from your furnace to the vents. I spoke to a service guy said it might be debris in Vents, or blocked Nov 22, 2019 · RV Furnace Blower Won’t Start. Oct 25, 2016 · 1. A little background. Make sure that your furnace blower isn’t damaged, and you can clean or replace it if it is the cause. Mission Statement: Supporting thoughtful exchange of knowledge, values and experience among RV enthusiasts. I have a 2000 Fleetwood Bounder with a Atwood 8520-IV-DCLP furnace in it. Most of the time it doesn't work at all. If I don't manually recycle it, the furnace will reset itself after an hour or so and try again. lubricate and clean the fans. Then, it is a possibility that there is a demand for heat coming from somewhere in the system but you may have run out of propane Jan 19, 2019 · My Atwood furnace will start but shuts off in a few minutes. Nov 22, 2022 · Check for moisture in your regulator and if it is frozen the gas won’t flow and the furnace won’t turn on for very long. Connect R and W wires together using a jumper wire or alligator clips. burner sounds irregular not a steady roar. It does run, but it doesn't always light. Good luck, DNR. Mar 21, 2024 · Give us a call at (314)230-9542. When I turn on the thermostat the fan comes on and when I go outside I can hear the igniter firing and smell propane, but after a minute or so and the igniter attempts to light 3 times the fan cuts off and the fault light flashes three times indicating an ignition lock out. Satisfied Customers: 304. Fix damaged bracing and tighten slack hardware. When it shuts off and the temp drops, it won't heat again until the next day. 1997 Ford 7. This high pitched squeal typically occurs shortly after the blower start running, or sometimes after it has Nov 6, 2020 · YES ---both have 12VDC then turn thermostat OFF and see which one goes dead. My heat pump (Atwood AC-1511) has been cycling every minute. IT can be caused from wasp's nests inside the furnace. It’s an affordable alternative Dec 19, 2010 · Atwood furnace burner cycling on and off. I have checked the gas lines, re routed the duct work and it still keeps happening. SidecarFlip. Experience: 22 years Diesel/RV,major engine, Chassis, Appliances, 14 Years Owner of successful Rv service center. Thaw out the regulator and put a cover on it. However, during these times the furnace should be My 28. Let the dealer fool with it. Flawed Igniter. 1. My current problem is that neither the furnace nor the AC fan will turn on (they worked fine last season). Atwood Furnace won't start (Hummingbird 17RB) I bought a lightly used 2017 Hummingbird 17RB. A reset button looks simple in the furnace. Answered in 16 minutes by: RV Mechanic: RV SPECIALIST. Feb 8, 2021 · A furnace short cycling could happens for multiple reasons. The blower comes on. RV You must check the battery and make sure it is 100% charged. Disconnect wires once furnace is running well. This is why you should begin by ensuring that all of these are firmly connected. Note that short cycling may cause bigger issues, so it’s best not to DIY this repair. Feb 13, 2016 · Atwood furnace won't kick on. That should be checked at least once a year. The blower may turn off eventually once everything is cooled. As soon as the heat exchanger cools down, though, the burners turn back on (because the thermostat is still Mar 20, 2023 · Answer: You can troubleshoot and fix your furnace by cleaning or replacing the air filter, checking the thermostat settings, inspecting the blower motor, clearing clogged air ducts, repairing the ignition system or flame sensor, and implementing prevention techniques like regular maintenance and proper insulation. Your fan limit switch will have a small white button on the lower left corner. If the air is clear, you need to turn the gas valve on. Air is in the propane line. Just started doing this last week. Location: Raleigh. We tried to turn it off and on many times like the instructions say but nothing. Jan 17, 2019 · Join Date: Jan 2019. Works fine once. Need a little troubleshooting help on Atwood model AFMD 35141 MH propane furnace. I have a 2011 Fleetwood terra with an Atwood 8520 furnace that will not start. Ignition lock out fault. Atwood hydro flame furnace requires a lot of power to run. 3 OBS 4x4 CC LB. The unit automaticall … read more Dec 28, 2014 · I shut down the whole electricity and also the switch on my furnice and waiting a few minutes to turn all back on. Posts: 44. The furnace turns on and runs normally and produces heat for five minutes then shuts down. The burner does light and some heat does come out of the ducts but the burner shuts down after around 5 minutes. Posts: 12. Mobile RV tech came out and said that my model Atwood furnace was known to have sail-switch failures. A clogged filter limits the amount of cool air that passes over the heat exchanger, causing it to overheat and shut off. Atfer 20-30 seconds, the burner relights, and again shuts down after several seconds. Furnace shuts off before it reaches the desired temperature. Apr 9, 2022 · 2004 Pioneer 28TB, purchased 3 years ago from dealer. Heat nor AC has been turned on Jan 3, 2006 · If you can find the flame jet, then the sensor is right in front of it. Blower turns freely, not frozen up. A Blue Thermostat + wire was capped off and not connected. Oct 19, 2020 · If the furnace motor doesn’t start when you turn up the thermostat, the possible problems are the fuse for the furnace, the thermostat, the module board, the small fan relay that is separate on older model furnaces, or the motor itself. Apr 24, 2017 · I have a 2003 Sunline 2363 and it has a Atwood 8520 IV DCLP 20,000 When I turned off the T stat and turned it down the furnace was still starting the fuel and the burner didn't turn off as it should when you turn the T stat down. Limit switch air flow fault. The furnace fan starts up. Filthy air filter. Last fall, the fan would come on, but no heat would be generated. A few seconds later the furnace clicks. Mar 5, 2021 · The quickest way to test a circuit board for your water heater is to use the circuit board from your Hydroflame furnace if you have one. t See full list on getawaycouple. May 17, 2023 · Lance camper Atwood furnace. OK, so everything checks out, control board tests good, replaced sail switch and limit switch but the blower will still not come on. Check for a dirty air filter and replace if needed. If you don't change your air filters often enough, the filters will become dirty and clogged, which means the heat exchanger retains heat and eventually causes it to overheat. I am guessing this issue might be caused by the flame sensor. We used it for about 2 weeks before we hooked it up to power. Inspect the wiring in your thermostat if it triggers your furnace to go off every 5 minutes. Control board turns on the blower 3. A. Next, make sure there is power going to the furnace. Any suggestion. I replaced the analog thermostat with the Dometic analog thermostat which has not solved the problem. There are several indirect issues that cause low airflow. When heat is called for the heat pump compressor will start Dec 31, 2017 · If you do not see an on/off switch near the thermostat or in the control panel that you use to control the other components in your vehicle then usually the on/off switch is built into the thermostat itself. Atwood furnace model 8535. If it still does not work you can try another reset with disconnecting the Aug 27, 2021 · Check your filter if your furnace runs every 5 minutes and clean it to remove the clog that causes overheating. Have an Atwood AFMD35121_A furnace that is inoperative at the moment. I had not even touched the thermostat or anything It just comes on and won't shut off. 35K Bounder - AFMD35141 Atwood Furnace. This is to do with the electrical source. But when it needs to start back again it will lite up the fire and turn off about 3 times but never turn on. The rear furnace has some problems. Make sure the stove then lights up again and then try the furnace. The remotes (which have been lost or accidentally thrown out) turned on power for AC units as well as the floor heat (Atwood Hydroflame Furnace). I'm at wits end on this. The 15 amp fuse is located in the hall in a box that has all the fuses and breakers. Oct-18-2020 04:30 PM. Could also be a defective sail switch, but probably not since it starts and runs for awhile. If the ignitor becomes defective, there will be no propane ignition. We are running on shore power. The furnace is a Concord 90% Efficient, gas fired, forced hot air unit with a White-Rodgers mercury switch thermostat, 5 years old. Feb 10, 2023 · Furnace will not light – Blower does turn on. I bought it from the original owner about 5 years ago. Atwood heat pump cycles on and off. Handy tools to always have:WorkPro Driver set: https://amzn. Open the main panel on the furnace and take out the filter. We've found that if we should off thermostat for at least 30 minutes, we can turn back on and it works normally for anywhere from 4-10 hours and then quits with the heat. Nov 13, 2020 · On Rv starts, runs, ignites for. I have a Atwood 8531-IV DCLP furnace that will not come. The mechanical thermostat is very difficult to turn on. Here's the scenario: Temperature gets down to the setpoint of the thermostat. ,the flashing light indicates one of these is the cause. I've done quite a bit of troubleshooting. Oct 14, 2013 · If you turn it off and then back on and reset the thermostat it may ignite and work properly. 5 RSTS furnace also wouldn't light. This will ensure your safety while working on the thermostat. If you are experiencing no hot water from your Atwood 7920-II RV furnace, then you will most likely feel like the entire appliance has broken down. Mechanic's Assistant: Have you checked to make sure the thermostat is working? What about the coolant level? Yes, My bedroom furnace is running. A dirty air filter is the most common cause of short-cycling. Oct 13, 2016 · Atwood Furnace AFMD35121A problem. Posts: 3. Atwood furnace won't stay running. Oct 6, 2020 · About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright Step 2: Make sure the white button is NOT pressed in. Jun 28, 2023 · Turn off power supply, then remove thermostat wires from control board. Feb 21, 2017 · 2. He Atwood furnace in our 2010 Suncrusier fires up air shuts down after around 5 minutes. Posts: 152. Turning On The Furnace FIG. So it goes without saying that if the igniter refuses to work, your Atwood hydro flame furnace won’t light. 2018 Airstream Sport 22ft Atwood Hydroflame Furnace (I think AFMD20)When activating the furnace by turning the thermostat on, the blower blows cold air for 30 seconds and shuts off. After shutting don, the rocker switch by the furnace on the rig exterior is observed to have tripped. Jan 2, 2010 · Furnace Problem (Atwood 8531-IV-DCLP) The furnace lights after 7 seconds, stays lit 10 seconds, then the flame goes out. Here is a step-by-step process on how to reset the Atwood furnace. If your furnace keeps shutting off, it could be due to low airflow. Aug 20, 2017 · Reply. May 9, 2020 · 1. The furnace should start after 15-30 seconds. Feb 9, 2011 · Atwood Furnace Squealing Noise. the fan runs then turns off after a minute, with no attemp to ignite, your sail switch has failed or is sticking (chen with a ohm meter to verify) if 2, double check fuses. ”. I tried disconnecting and have the same issues when running off the battery. We have been using shore power since we had a new furnace installed in Nov. Oct 16, 2021 · Atwood 7920-11 Furnace won’t shut off. It has been coming on randomly at night and blowing air into my camper. When I got home to a cold RV I found out that Aug 11, 2019 · I am having an issue with my Airstream furnace. IT can be caused from the LP pressure being too low at the tank regulator. An average furnace will in fact turn off and on only a couple times in an hour. com Nov 21, 2022 · If the RV furnace runs and then shuts off, the main issue has to do with the switch assembly. Sure enough , sail-switch was bad , replaced and Bob's your Uncle. Nov 29, 2022 · Join Date: Sep 2020. You need to make sure the thermostat is set on the heater and turned on. • Turn OFF all power to the Furnace at the main power supply . If your interior temperatures decline again, your furnace will power back on. May 8, 2019 · The sequence of operation (at least for my furnace) should be: 1. Last year I replaced my two ac roof units. The gas valve is receiving power, as is the igniter. Any suggestions would be appreciated. Atwood Furnace - Blower Won't Start. Nov 3, 2018 · 1. Aug-20-2017 01:59 PM. RV SPECIALIST, RV Mechanic/Diesel Mechanic. Here’s a step-by-step guide on how to do it: Disconnect the power: Begin by turning off the power to the furnace at the breaker box. 3. Purge the air by turning on other appliances (like a cooktop) that are further downstream from the propane tanks. Igniter attempts to light the burner three times. I have replaced the limit switch, sail switch and circuit board but when you turn furnace you get nothing out of front furnace but rear furnace works fine. if 3, your flame sense/ignitor failed. Atwood 8520-IV-DCLP furnace. Check the gas lines and the ignitor. The pattern on a properly functioning RV furnace should be (1) blower fan comes on for as much as 30 seconds (allowing the electronics to confirm good air flow), (2) clicking of the ignitor, (3) WHOOSH/RUMBLE of the burner igniting, and then (4) AHHHHHHhhhhhhhh as the warm air starts flowing! 😉. To fix the issue, remove the cover to access the switch, remove the switch assembly, clean behind it, and then re-attach everything. The next troubleshooting is to check whether the furnace tank is turned on and the gas is flowing. After you activate the furnace, the igniter would generate sparks and ignite the propane gas. Sail switch confirms air flow. Contact Atwood with any additional questions or problems. First of all, some thermostats control both the furnace and the air conditioner. Once done, restart the RV furnace and it will work. Flame sense fault. 5 inches with half the appliances running,a simple way of checking this is light all four burners on the stove,turn on the water heater and furnace,when they try to light,watch the burners,they should stay high,if they fade Issues with aging, rust build-up, and corrosion are known to be the 3 main culprits behind a defective thermostat. Attwood 8531 furnace blower not working. Nov 5, 2017 · Join Date: Nov 2017. Aug 18, 2021 · This is an Atwood 8535-IV that wouldn't turn on. It has an Atwood Hydro Flame series AFS furnace. If it doesn’t get the required power, the unit will not respond. 1 Power Switch (Small Vent Models) FIG. Nov 7, 2015 · Atwood 8520 furnace will not start. Remove the thermostat cover: Use a screwdriver to remove the screws holding the thermostat cover in place. 3 times is the key. a minute later it will do it again. Depending on the type, quality, and size, air filters will cost anywhere from $5 to $100 to replace. Good morning, I have a Dometic DFMD35121. to/3LH51ZMFuses Flat: Nov 13, 2019 · My Atwood Furnace model AFMD35131 will not light. IF resetting the switch does not work then it gets more complex, you would need to locate the circuit board on the furnace and see if voltage is getting to the plug connector when the thermostat is turned ON, if you have voltage on the connector when thermostat is on then I would have the I have a 1997 Terry 30g RV with an Atwood 8531-III DCLP furnace and a Coleman 7300 air conditioner. Mar 30, 2017 · The furnace is a Atwood brand I believe a series AFM. On any appliance the first thing to check is the gas pressure,it needs to be 11. Try this as least 4 or 5 times. And thus, it results in the issue of the RV furnace shutting down too early, and there are fewer chances of having hot air inside your RV. It keeps doing that over and over. Propane is good. It's now February and going to be -3 tonight with a 20mph wind. I am hooked up to 15 amp power Battery is 90% Propane tank is full Temperature outside is -2I have checked the . If you have 12VDC at those 2 Blue wires (Pin 3 and pin 2) then you should have 12VDC to furnace from the thermostat. However, you should note that this most likely means that the wiring on your device has been damaged. Then turn on the propane. However, there is most likely a failure of one of the many internal components. Then nothing happens at all. Set the filter aside to dry, and reinstall it before starting the furnace back up. Bought Bounder 33c new in 2016. It is unfortunate to see a broken or bad igniter on your RV furnace. Being I was putting it away for the season, I figured I would dive into it when spring arrived. Because the instruction book isn't clear, I am not sure if I am doing something wrong, or the furnace Oct 1, 2018 · 4. I am getting the air flow/ limit fault. When the system is working, the thermostat does keep the house properly conditioned. A dirty blower wheel is another likely culprit for your furnace turning on and back off too quickly due to airflow issues. The unit will turn on and run for maybe 10-15 minutes and shut off. Turn thermostat to heat and hear a click. When I turn on the furnace, blower comes on for a few seconds, then the gas and ignitor - it ignites and burns for about 5 sec (with ignitor clicking entire time), then gas and ignitor shut off, blower continues for 10 seconds, then it cycles two more times, then shuts off. We replaced the ICCB last November when it did the click click thing but wouldn't stay ignited. Resetting the Atwood furnace ignition lockout fault is the most common solution. If the button is pressed in, the switch is set to Manual and is Nov 11, 2019 · The Atwood furnace on my 23 month old RV isn't operating. You have to be patient but it will work out as you want it to. My ATWOOD Model 8535-IV Runs off a comfort control combo thermostat that runs both my A/C and my Furnace. Posts: 8. When trying to use Atwood Furnace, the most common issue people have with it is that the device is not working. Blower will run for 30 seconds and then it shuts off. Lack of Heat. This is generally a good rule of thumb to follow. Even if I try running just the fan without AC, it doesn't turn on. Spring has arrived and I dove into it. Mar 6, 2018 · Join Date: Oct 2017. Turn off and unplug the furnace if the heat seems low or inaccurate. • At the exterior access panel, turn the switch on the Furnace to the OFF position . Sep 13, 2020 · The problem is after - as noted - a week or a day - of normal operations, the furnace will suddenly not respond to my temperature setting on the thermostat. Feb 18, 2011 · Hi, Here is a service manual on the unit,it will explain in detail what I'm talking about. Any thoughts would be very Quick diagnosis on steps for heater not working in rv motorhome trailer. The circuit board gives one flash in three seconds indicating air flow/limit fault. Verified. Moving the temp control makes no difference, ONLY toggling the on/off switch on the thermostat will kick on the furnace. My Atwood 8535 IV furnace is making an intermittent squealing noise of varying pitch and amplitude, blower rotation actually seems quiet, it is more like a high pitched vibration as versus rotation noise. Fan came on for 20 seconds and then stopped . Repair parts:Controle Board: https://amzn. Apr 5, 2022 · 1. Robert. Blower turns on. Apr 26, 2015 · The furnace burner shuts off prematurely when one of two things happen: 1. checked the sail switch is working, replaced the limit switch. k. Do not force the valve if you cannot turn it to the on position. Solution #01: Reset the Atwood Furnace. Propane tank full. Adjust the thermostat. Oct 18, 2020 · Atwood Furnace - Ignition Lockout Fault. Oct 26, 2023 · Short cycling, in the simplest terms, is when your furnace keeps turning on and off repeatedly. Dec 9, 2023 · Posts: 270. Turn back on power supply. The RV Mechanic I'm going to connect you with knows all the May 28, 2011 · I have an Atwood 8531 Hydroflame furnace, orginal to a 2005 Tioga 22B class "c" RV. Next—remember that the thermostat operates from the 12-volt DC coach battery—ensure that your battery is fully charged and then check the 12-volt fuse panel to make sure the furnace fuse isn’t blown. We turn on the thermostat and hear a click. it does not start the heat pump compressor when it does this. After another 20-30 seconds it relights a final time, turns off Jan 10, 2021 · Furnace keeps turning on and off. Thermostat quit working on AC and heat 6 months ago. BTW, this problem can also occur on your home furnace, water heater or gas stove, so before calling the repairman ($80+ per hour) look at the thermocouple. To get the furnace to restart I turn the thermostat off and on again and it starts. braygor. This knowledge guide is going to give Oct 28, 2023 · Following these six procedures will make it easy to quiet a loud RV furnace: Clean the furnace’s filters, vents, ducts, and exhaust systems. Dec 3, 2018 · Hi have a Atwood RV furnace, it will light then turn off after just about 30 40 seconds of running, then will relight again. 4. Most of the time, it is available over the circuit board. That can cause the furnace to overheat and forces the high limit switch to ride to the rescue by shutting the furnace off. But nothing else, fuses are all good. I have a 8531 that keeps shutting off. I turn off thermostat switch and turn it back on. The first time the temp dropped into the 40s inside - I woke up cold and that was the start of it. 2. This repeats three cycles and then the furnace doesn't light off anymore until the power is turned off and on again. More to follow. Also, after it runs for a while, the burner stops (even though the thermostat calls for heat) and the fan keeps running. That button tells the switch whether to operate manually (run the fan all the time) or automatically (run the fan only during heating cycles). Dirty Air Filters. Posts: 187. Broken Or Bad Igniter. Then the fan will shut off. This video shows how I diagnosed the problem. ATWOOD Model 8535-IV DCLP Unit won't stop running. Category: RV. The method is called Atwood furnace ignition lockout A short cycling furnace will turn off and on repeatedly in a very short period of time. 01 F250 SD 4x4, SB, Diesel, K&N Air Filter towing 01 Timberland 28FBS. Vocational, Technical or Tra 25,358 satisfied customers. In many cases, igniter failure is caused by the gap at the ends of the device electrodes exceeding design specification. If you do, then there is a leak, and do not turn the furnace on. Posts: 57. atwood furnace burner cycling on and off. No electricity- this is not due to bad wires or loose connections. Try turning off the thermostat completely and wait a few minutes turning off propane as well. Cannot Turn On Atwood Hydroflame Furnace Heater. cleaning the sail switch to fix a RV furnace that starts then shuts down Jan 12, 2021 · After the cool-down cycle the blower shuts down. RV Mechanic. If the air filter is clogged with dirt, it won’t allow proper air flow to the heat exchanger. 6v power to board and on/off switch. I am having trouble starting it up. When you turn the temp all the way down you should feel it click when sliding all the way down which is then usually the off position. The furnace will turn on for about 15 second then shut off. If you repeatedly turn it off and on, so that the burner and plenum heat up, then it may stay on long enough May 2, 2022 · Sometimes, like the Atwood design, the furnace is designed to run the blower until the thermo-heat relay has cooled enough for the blower to turn off. Lock out, blower remains on but no further attempts to light it. bs vq sj zj zi eu re vn wq cf